BLH DXt-15 Tension Transmitter Specifications and Dimensions*
![]()
DXt-15 transmitters add high accuracy, 50,000 count resolution to T-MAC web tension measuring systems. Precision tension measurement signals from LTT, HTA, or HTZ transducers are measured, processed, and displayed on the front panel meter. Simultaneously, LTT, HTA, or HTZ signals are transmitted through the analog and serial outputs. Digital filtering ensures stable display readings and smooth output signals for brake and motor drive controls. The DXt-15 contains an internal multi-cell summing circuit, 10 or 15 volt excitation, and digital RS-485 or Allen-Bradley Remote l/O outputs. Sum and difference measurements can be acquired by installing a DXt-15 transmitter at each end of the roll. |
Resolution: | 50,000 counts |
| Conversion Speed: | 50 msec | |
| Calibration Repeatability: | 0.3 µV per count | |
| Linearity: | ±0.01% full scale | |
| Dead Load Range: | 100% full scale | |
| Power: | 10 watts max. | |
| Analog Output: | current selectable 12 bit D-A | |
| Input Voltage: | 117/230 Vac ±15% @ 50 or 60 Hz |
|
| Display Type: | 3 1/2 digit LCD with trailing zero |
|
| Available Interface Capability: |
Allen Bradley Remote I/O Modbus RTU |